Developing, manufacturing and selling medicines in Japan, the US and Europe requires a clear grasp of how their regulations differ. International harmonization through ICH and PIC/S has brought quality thinking closer together, but significant differences remain in regulatory structure, approval pathways, who is responsible for batch release, and how inspections work. This guide compares Japanese, US and EU pharmaceutical regulation across authorities and legal frameworks, approvals, licensing and responsible persons, GMP and release, inspections, electronic records, clinical trials, post-marketing and medical devices, and sets out practical points for companies operating globally.
What you will learn
- The regulators in each region and the laws behind them
- How approval pathways differ (Japanese marketing approval, US NDA/BLA, EU centralised procedure, etc.)
- Who is responsible for release (Japan’s three responsible persons, the US quality unit, the EU QP)
- GMP, inspections, electronic records, clinical trials and pharmacovigilance compared
- Medical device differences, including the US QMSR that took effect in 2026
- How to design a global quality system and ERP around these differences
1. Regulators and legal frameworks
| Japan | US | EU | |
|---|---|---|---|
| Regulators | Ministry of Health, Labour and Welfare (MHLW) and the Pharmaceuticals and Medical Devices Agency (PMDA); prefectures handle some GMP inspections | Food and Drug Administration (FDA): CDER for drugs, CBER for biologics, CDRH for devices | European Commission, European Medicines Agency (EMA), and national competent authorities (NCAs) of member states |
| Core law | Act on Securing Quality, Efficacy and Safety of Pharmaceuticals, Medical Devices, etc. (PMD Act) and related ministerial ordinances | Federal Food, Drug, and Cosmetic Act; Public Health Service Act (biologics); Title 21 of the Code of Federal Regulations | Directive 2001/83/EC (human medicines), Regulation (EC) No 726/2004 (centralised procedure and EMA), and others |
| Structure | National approval, with oversight by the state, PMDA and prefectures | A single federal agency approves and oversees | Two layers: EU law plus national law; inspections are mainly carried out by member states |
EU pharmaceutical reform: the EU is undertaking its first comprehensive overhaul of pharmaceutical legislation in about twenty years (the “pharma package”). The European Parliament and Council reached a provisional agreement in December 2025. EMA anticipates entry into force in 2026, followed by a 2026–2028 transition period while member states update national law. Please check the latest status of formal adoption and application dates; we have not confirmed them as of writing (November 2026).
2. Approval pathways
| Japan | US | EU | |
|---|---|---|---|
| New medicines | Marketing approval: PMDA reviews, the Minister of Health, Labour and Welfare approves | New Drug Application (NDA), Biologics License Application (BLA) | Centralised procedure (EMA assesses, the Commission authorizes, valid EU-wide), decentralised, mutual recognition and national procedures |
| Generics | Marketing approval (filed as a generic) | Abbreviated New Drug Application (ANDA) | Via the procedures above |
| Notable features | A GMP compliance inspection is required at approval, with periodic inspections afterwards | Pre-approval inspections (PAI) may be conducted | The centralised procedure is mandatory for biotech products, orphan medicines and certain others |
3. Licensing and responsible persons
The clearest difference among the three regions is who carries final responsibility for product quality.
| Japan | US | EU | |
|---|---|---|---|
| License types | Separates the marketing authorization holder business (responsible for placing on the market) from the manufacturing business (licensed per site) | Establishment registration and product listing | Manufacturing authorisation; marketing authorisation holder (MAH) |
| Key responsible persons | The marketing business’s “three responsible persons” (general controller, quality assurance manager, safety management manager) and each site’s manufacturing manager | The quality unit; no statutory individual qualification scheme | The Qualified Person (QP): at least one per manufacturing authorisation |
4. GMP and batch release
| Japan | US | EU | |
|---|---|---|---|
| GMP rules | GMP Ministerial Ordinance (revised effective August 2021 to align with PIC/S GMP and incorporate quality risk management and pharmaceutical quality system concepts) | 21 CFR Parts 210/211 (CGMP) | EudraLex Volume 4 (EU GMP Guidelines: Parts I and II plus annexes) |
| Release | Two steps: the manufacturer decides release from the site, then the marketing authorization holder decides release to market under the GQP ordinance | The quality unit approves or rejects each batch for release | The QP certifies each batch before release |
| Harmonization | All three take part in PIC/S (Japan joined in 2014, US FDA in 2011, EU member state authorities as participants). ICH Q7 (API GMP), Q9 (quality risk management) and Q10 (pharmaceutical quality system) form a common foundation | ||
Japan’s two-step release and the EU’s QP certification share the idea that a responsible person checks each batch before it reaches the market, but differ in who decides and on the basis of which records. When rolling out ERP globally, the question is how to reflect these differences in batch status management and approval authorizations.
5. Inspections
| Japan | US | EU | |
|---|---|---|---|
| Inspectorate | PMDA, prefectures | FDA | National competent authorities |
| Main types | GMP compliance inspection at approval, periodic inspections after approval, for-cause inspections | Pre-approval, risk-based surveillance and for-cause inspections | Inspections for manufacturing authorisations and GMP certificates, routine inspections |
| Publication of findings | Administrative actions are published | Form 483 observations and Warning Letters are public | GMP non-compliance shared via the EudraGMDP database |
| Mutual recognition | Mutual recognition agreements (MRAs) on GMP inspections exist between Japan and the EU and between the US and the EU. There is none between Japan and the US, but PIC/S is bringing inspection standards closer | ||
6. Electronic records and computerised systems
| Japan | US | EU | |
|---|---|---|---|
| Electronic records / signatures | ER/ES guideline (2005) | 21 CFR Part 11 (effective 1997) | EU GMP Annex 11 (2011 version; revision drafted in 2025) |
| Computerised systems | Guideline on management of computerized systems (2010) | Part 11 and related guidance (CSA guidance for devices) | Annex 11 |
| Data integrity | Guidance from FDA (2018), MHRA (2018), PIC/S PI 041-1 (2021) and WHO (2021) provides a common lens. See our data integrity guide | ||
7. Clinical trials
| Japan | US | EU | |
|---|---|---|---|
| Main rules | GCP Ministerial Ordinance; clinical trial notification | 21 CFR Parts 50 (protection of subjects), 56 (IRBs) and 312 (IND) | Clinical Trials Regulation (EU) No 536/2014, with applications centralized in the Clinical Trials Information System (CTIS) |
| Harmonization | ICH E6 (GCP) is the common foundation; ICH E6(R3) was adopted in January 2025 and is being implemented region by region | ||
8. Post-marketing safety
| Japan | US | EU | |
|---|---|---|---|
| Main rules | GVP ordinance (safety management), GPSP ordinance (post-marketing studies), re-examination system | Adverse event reporting (FAERS), Risk Evaluation and Mitigation Strategies (REMS) | Pharmacovigilance (GVP modules), periodic safety update reports (PSUR), risk management plans (RMP) |
9. Medical devices
| Japan | US | EU | |
|---|---|---|---|
| Quality system | QMS Ministerial Ordinance (aligned with ISO 13485) | Quality Management System Regulation (QMSR), effective 2 February 2026, under which 21 CFR Part 820 incorporates ISO 13485:2016 by reference | Medical Device Regulation (MDR, (EU) 2017/745) and In Vitro Diagnostic Regulation (IVDR); ISO 13485 is the harmonized standard |
| Market access | Approval, certification or notification depending on class | 510(k), PMA, De Novo, etc., depending on class | CE marking after conformity assessment by a notified body, depending on class |
With the QMSR in force, device quality systems in all three regions now rest on ISO 13485. The US still keeps its own requirements, such as labeling and packaging controls and UDI, so ISO 13485 certification alone is not sufficient.
10. Practical points for global operations
- Run one quality system set to the strictest requirement: separate regional systems scatter procedures and records. Keep a thick common core and hold regional specifics (Japan’s responsible persons, the QP, FDA certifications) as deltas
- Map responsible roles: list which approvals Japan’s responsible persons and manufacturing managers, the EU QP and the US quality unit each own, and reflect that in procedures and system authorizations
- Reflect release differences in ERP batch management: decide at design time how Japan’s two-step release, EU QP certification and US quality unit approval are represented in batch status, usage decisions and approval rights
- Meet all three electronic record regimes together: combine Part 11, Annex 11 and the ER/ES guideline into one set of requirements verified in one validation (see our CSV guide)
- Track regulatory change continuously: the EU pharma reform, the Annex 11 revision and the US QMSR all land in 2025–2026
Summary
Through ICH and PIC/S, Japanese, US and EU pharmaceutical regulation has converged on quality thinking, but differences remain in regulatory structure, approval pathways, release responsibility and inspection practice. Above all, who is responsible for releasing product to market — Japan’s responsible persons and two-step release, the EU QP, the US quality unit — directly shapes quality system and ERP design. For electronic records, see also our guides to Part 11 and Annex 11.
Talk to us about global regulatory alignment
For help aligning quality systems and responsibilities with Japanese, US and EU requirements, or designing ERP batch management including release, please reach out via our contact page.