Data integrity is one of the most frequently cited topics in pharmaceutical and medical device inspections. If test results and batch records are not kept “correct, unaltered and verifiable after the fact,” quality decisions themselves lose their basis. This introductory guide covers the definition of data integrity and the ALCOA+ principles, the main regulations and guidance documents, the deficiencies inspectors most often find, technical and procedural controls, and what to watch for when ERP and cloud systems are in scope.
What you will learn
- What data integrity means and why regulators focus on it
- The meaning of each ALCOA / ALCOA+ / ALCOA++ principle
- Key regulations and guidance from FDA, MHRA, PIC/S, WHO and Japan
- Typical deficiencies found in inspections
- Technical vs. procedural controls, and how to approach audit trail review
- Points to watch in ERP and cloud systems, and how to get started
1. What data integrity is
The PIC/S guidance on data integrity (PI 041-1) defines it as the extent to which all data are complete, consistent and accurate throughout the data lifecycle. The key phrase is “throughout the data lifecycle”: reliability must be maintained not only at the moment data is created, but through recording, processing, review, reporting, retention and destruction.
The idea itself is not new; GMP has always required accurate records. But during the 2010s, inspections around the world uncovered deleted test data, hidden retests and back-dated records, leading to warning letters and import bans. Data integrity has since been treated as a focus area in its own right.
Why it matters: Quality assurance makes decisions based on what the records say. If records cannot be trusted, batch release, deviation investigations and regulatory submissions all lose their foundation. Data integrity is not a single-procedure issue; it is the foundation of the entire quality system.
2. The ALCOA+ principles
Data integrity expectations are commonly summarized by the acronym ALCOA. The original five principles used by FDA were later extended with four more to form ALCOA+.
| Principle | Meaning | Practical example |
|---|---|---|
| Attributable | It is clear who recorded or changed data, and when | Individual user IDs; no shared accounts |
| Legible | Records are readable and permanent | No erasable pens; electronic records kept in readable formats |
| Contemporaneous | Recorded at the time the work is done | No later transcription from scrap notes; correct system clocks |
| Original | The first recorded data, or a true copy | Keep instrument raw data, not just transcribed values |
| Accurate | Free from error and reflecting what happened | Verified calculations; input checks |
| Complete | All data retained, including repeats and aborted runs | Failing results and trial injections are not deleted |
| Consistent | Sequence and timing can be followed without contradiction | Timestamps match the order of the procedure |
| Enduring | Not lost during the retention period | Backups; protection against media degradation |
| Available | Can be retrieved and presented when needed | Records can be produced promptly during an inspection |
Some documents add Traceable and call it “ALCOA++.” Naming differs by document, but the substance is largely the same.
3. Key regulations and guidance
| Issuer | Document | Role |
|---|---|---|
| US FDA | Data Integrity and Compliance With Drug CGMP: Questions and Answers (December 2018) | FDA’s thinking on data integrity under drug CGMP, in Q&A form |
| US FDA | 21 CFR Part 11 (electronic records and signatures) | Federal regulation for electronic records and signatures. See our Part 11 guide |
| UK MHRA | GXP Data Integrity Guidance and Definitions (March 2018) | Covers GxP broadly, not only GMP but also GLP and GCP |
| PIC/S | PI 041-1 Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments (effective July 2021) | Detailed guidance written for inspectors; essential for understanding how inspectors think |
| EU | EU GMP Annex 11 (computerised systems) | Requirements for computerised systems. See our Annex 11 guide |
| WHO | Guideline on data integrity (2021, Technical Report Series No. 1033, Annex 4) | Referenced in WHO prequalification and elsewhere |
| Japan | ER/ES guideline (2005), guideline on computerized systems (2010), revised GMP Ministerial Ordinance (effective August 2021) | The revised ordinance aligns Japanese GMP with PIC/S GMP; data integrity was one of its main themes |
Japan joined PIC/S in 2014, and domestic inspections now look at data with the same lens as PIC/S guidance. Even companies that do not export cannot avoid data integrity.
4. Thinking in terms of the data lifecycle
| Stage | What to check |
|---|---|
| Creation / acquisition | Are instruments and systems configured correctly? Is raw data saved automatically? |
| Recording | Is it recorded who entered data and when? Is transcription avoided? |
| Processing / calculation | Are formulas and processing parameters verified? Is reprocessing history kept? |
| Review | Are audit trails and metadata reviewed, not just results? |
| Reporting | Is data selectively reported? |
| Retention / archiving | Will data remain readable throughout retention? Are backup and restore tested? |
| Destruction | Is data destroyed by an approved procedure once retention ends? |
A practical starting point is to draw a data flow diagram for critical data (release test results, batch records and so on) covering this entire flow.
5. Typical deficiencies found in inspections
- Shared accounts: several people use the same ID on an instrument PC, so it is unclear who did what
- Audit trails disabled or never reviewed: the function exists but is switched off, or nobody ever looks at it
- “Trial injections”: unofficial runs before the official test, with the data deleted afterwards
- Deletion or overwriting: ordinary users have rights to delete data
- Clock changes: users can change the PC clock, so timestamps cannot be trusted
- Local storage: raw data sits only on the instrument PC and is not backed up
- Paper vs. electronic mismatch: printouts are treated as the “original” while electronic raw data is not retained
- Selective reporting: out-of-specification results are retested without investigation and only passing results reported
Most of these arise from weak systems and habits rather than malice. The basic approach is to prevent them through system configuration and procedures, not individual vigilance alone.
6. Technical and procedural controls
| Area | Technical controls (prevent with the system) | Procedural controls (prevent with rules and operation) |
|---|---|---|
| Access | Individual IDs, role-based permissions, password policy | Procedures for creating and removing IDs; periodic access reviews |
| Preventing alteration | Deletion and overwrite disabled; audit trail always on | Reason recorded for corrections; approval procedure |
| Time | Synchronization with a server clock; users cannot change the clock | Periodic checks of time settings |
| Storage | Automatic saving to the network; scheduled backups | Periodic restore tests |
| Review | Audit trail reports; automatic exception flags | Defined audit trail review procedure and frequency |
Some systems, such as older instruments or spreadsheets, cannot support adequate technical controls. In that case, compensate with procedural controls and plan for replacement.
7. Approaching audit trail review
An audit trail automatically records who changed what, when and why. What matters is not that it is recorded, but that it is actually reviewed.
- What to review: focus on actions that affect quality — data changes and deletions, reprocessing, permission changes, clock changes
- When to review: for data used in release decisions, before the result is approved; system-level audit trails periodically
- How much to review: reading every line is unrealistic; scope the review by risk and use formats that surface exceptions (activity late at night, rapid repeated runs, etc.)
8. Data governance and culture
Data integrity cannot be achieved by system settings alone. All the guidance documents call for data governance — organizational arrangements that make integrity the norm.
- Senior management signals the importance of data integrity and allocates resources
- Build a culture where unfavorable results can be reported (excessive pressure to “get results” breeds falsification)
- Train staff down to the bench with concrete ALCOA+ examples
- Check data integrity regularly through internal audits and self-inspections
9. ERP and cloud systems
Data integrity discussions tend to center on laboratory instruments, but ERP is in scope too. Whenever ERP handles GMP-relevant data — material masters, inspection results, usage decisions (release decisions), batch records — the same principles apply.
- Change history: is change history retained for masters and documents? In SAP, check which objects are covered by change documents and table change logging, and how long they are kept
- Authorizations: are GMP-relevant entry and approval rights separated in line with segregation of duties?
- Electronic signatures: where approvals are electronic, is it linked to the record who signed, when, and with what meaning?
- Interfaces: when data moves from instruments, MES or LIMS into ERP, can loss or alteration occur along the way?
- Cloud / SaaS: are data location, backups and the provider’s change management confirmed through contracts and supplier assessment?
For the relationship with system validation, see our CSV guide; for a concrete ERP approach, see GAMP5 × SAP: Validation Design Guide.
10. How to get started
- Inventory: list the systems and paper records that handle GMP data
- Data flow diagrams: map the flow of critical data from creation to retention
- Risk assessment: prioritize by data criticality and the likelihood of alteration or loss
- Gap analysis: identify technical and procedural gaps against ALCOA+ and regulatory expectations
- Remediation: change settings, revise procedures and upgrade systems in priority order
- Sustain: embed audit trail review and internal audits in operations, and keep training
Summary
Data integrity means keeping data correct, unaltered and verifiable from creation to destruction. Use ALCOA+ as a common language, protect data through both system configuration (technical controls) and rules (procedural controls), actually review audit trails, and support it all with organizational governance. For electronic record requirements, see also our guides to 21 CFR Part 11 and EU GMP Annex 11.
Talk to us about data integrity
For help mapping data flows across ERP and surrounding systems, running gap analyses or setting up audit trail review, please reach out via our contact page.